2009 UNIFORM PLUMBING CODE PDF

adminComment(0)

The advantages of a uniform plumbing code adopted by various local jurisdictions The Uniform Plumbing Code is supported by the American Society of. PDF Drive is your search engine for PDF files. As of today we have Complete copies of the Uniform Plumbing Code as published by the. International. Directory of Listed Plumbing Products for Manufactured Housing and Recreational The daily IAPMO UPC IAPMO UMC (): Uniform Mechanical Code.


2009 Uniform Plumbing Code Pdf

Author:SIGNE DARRAS
Language:English, Arabic, French
Country:Morocco
Genre:Fiction & Literature
Pages:299
Published (Last):06.05.2016
ISBN:341-7-26310-146-1
ePub File Size:29.31 MB
PDF File Size:12.51 MB
Distribution:Free* [*Sign up for free]
Downloads:31643
Uploaded by: JULIANNE

Complete copies of the Uniform Plumbing Code as published by Uniform Plumbing Code, Standards and amendments – WAC The primary rules governing the processing of the Uniform Plumbing Code and Uniform .. Report on Proposals and Report on Comments in digital Adobe PDF. ASTM A (R) Gray Iron Castings for Valves, Flanges, and Pipe. Uniform Plumbing Code (UPC) - Download as PDF File .pdf), Text File .txt) or read online.

What is a Redline? A redline document shows additions, deletions and other content and formatting changes between the active standard and the previous edition. If you download a redline upgrade, you will receive TWO versions of the document — the current edition of the standard and the redline version. How to download To upgrade your document to include the redline version: Add the document to your cart.

Select the Upgrade with Redline option in the cart pop up. Multi-User PDF files allow you to download access to specific documents for use in your company for up to nine users. Select your desired number of users. A redline Multi-User document gives you the both the ability to compare all the changes between the active standard and the previous version and to provide you with access for up to nine users.

Use Redlines To: Identify updates in minutes, not hours Effortlessly implement changes to procedures, equipment and products Save time and resources When you download Techstreet redlines, you receive TWO documents -- the clean, active version of the standard and the redline version.

There are corrections to this edition, which are available as separate documents. The clothes washer shall discharge through an air break into the primary receptor standpipe. Special consideration shall be given to every fish.

An American National Standard

A grease interceptor shall be provided for proper handling of liquid wastes containing grease. Floor sinks shall be installed flush with the finished floor and shall be accessible for cleaning. Fixtures such as.

A grease interceptor as described in these standards shall be installed in any business establishment with kitchen facilities including restaurants. All other indirect waste piping shall discharge into the secondary port through an air gap. The waste discharge from fixtures and equipment which may contain grease from the businesses set out previously shall be drained through a grease interceptor or grease interceptors.

Each fixture discharging into a grease interceptor shall be individually trapped and vented in an approved manner. For business establishments other than commercial restaurants. The fittings shall be installed in the following manner: A sanitary tee shall be installed at the inlet.

Grease interceptors shall be so designed that they will not become air bound. Page 6.

Interceptor covers shall have a minimum opening dimension of twenty 20 inches mm in diameter. Such designs shall be prepared by a Nevada Registered Engineer.

Any leakage below this level is cause for rejection. Cleanouts shall be installed in the drainage piping inlet and outlet side of each grease interceptor and the outlet side of each sample box. Interceptors shall not be backfilled until the inspection has been made to verify there are no leaks.

A minimum of one access point into each compartment within the separator shall be provided. An accessible hose bib shall be located within 25 feet mm of every grease interceptor.

A water test shall be applied to the level of the top of the interceptor inlet opening through the outlet opening or discharge side of the sample box. Multiple business connections to a single interceptor are not permitted.

Location of all grease interceptors shall be shown on the approved plans. Each interceptor shall be properly vented with a relief vent located on the outlet side of the interceptor.

Uniform Plumbing Code Books

Structural calculations to verify its adequacy may be required. Each grease interceptor shall have an approved water seal of not less than two 2 inches Interceptors shall not be more than one size larger than required in Table When grease interceptors are located in areas of pedestrian or vehicle travel.

Grease interceptors shall be so located as to be accessible for service without the use of ladders or the removal of bulky equipment.

There shall be adequate access for cleaning all areas of the separator. All waste shall enter the grease interceptor through the inlet pipe. Interceptors shall show no leakage from section seams. Unless approved by the sanitation authority in writing. Separator covers shall be of gas-tight construction.

For situations not covered by Table In addition. Grease interceptors shall be sized in accordance with Table Each grease interceptor shall serve only one business establishment. Interceptors as described in these standards shall be installed in. An interceptor shall be provided for the proper handling of liquid wastes containing oil of petroleum origin. The waste discharge from fixtures and equipment which may contain sand. This requirement includes. Submittal of a written application describing the exact facility operation and the types and anticipated volumes of waste to be generated may be required by the building official.

Access covers shall have a minimum opening dimension of twenty 20 inches mm in diameter. The waste line from toilets.

Top Selected Products and Reviews

A minimum of one 1 access point into each compartment within the separator shall be provided. Design standards other than those listed above may be acceptable.

When separators are located in areas of foot or vehicle traffic. Whenever an existing building has a change in use which requires an interceptor or whenever there is an increase in the total number of drainage fixture units served by an existing interceptor. The materials removed from interceptors shall be handled and disposed of in a proper manner in accordance with published health district and sanitation authority requirements.

Redwood baffles shall not be used for new or existing interceptors. Any private or public wash rack or slab used for cleaning machinery or machine parts. Illegal dumping of waste into the sewer shall not be allowed. Abandoned interceptors shall be cleaned and filled as required by Section Page 8.

No such collected grease. Separate owners or lessees within a large business or establishment shall require separate interceptors. Any alternate design shall be prepared by a Nevada Registered Engineer and submitted for review and approval by the sanitation authority and the building official.

Structural calculations performed by a Nevada Registered Engineer to verify adequacy may be required. Where the conduit terminates within a building. Combining Storm with Sanitary Drainage. Products listed for such use. Page 9. Filter media shall be provided for exterior subsoil piping. All gas piping under a slab shall be capable of being removed and replaced. The conduit shall extend to a point at least 12 inches mm beyond any area where it is required to be installed or to the outside wall of a building.

Paved Areas.

Southern Nevada shall be considered a dry gas condition area unless specified by the local gas purveyor. No gas piping shall be installed in or on the ground under any building or structure unless installed in gastight conduit.

The conduit shall be of material approved for installation underground beneath buildings and not less than Schedule 40 pipe.

Such subsoil drains may be positioned inside or outside of the footing. Traps on Storm drains and Leaders. Joining tubing by brazing see Section Fittings listed for use in concealed spaces that have been demonstrated to sustain. Where necessary to insert fittings in gas pipe that has been installed in a concealed location. Test Gauges. This inspection shall include an air. Delete Chapter Firestop Protection.

Part 1. Gray Water Systems. For welded piping. Where gas piping is to be concealed. Test pressures shall be held for a length of time satisfactory to the Administrative Authority. Page Connections shall be of the following types: These tests shall be made using air.

All necessary apparatus for conducting tests shall be furnished by the permit holder. Test gauges used in conducting tests shall comply with Section Revise item 4 in Section CO2 or nitrogen pressure test.

Sections through in their entirety. Potable water supplied as makeup water in these systems shall be protected against back-pressure and back-syphonage in accordance with Sections Firefighter Breathing Air Replenishment Systems.

Private Sewage Disposal Systems.

Delete Appendix K. Delete Appendix F. A The provisions of Part II of this chapter shall not be allowed in residential buildings and shall apply to the installation.

2009 Uniform Plumbing Code

Flag for inappropriate content.Select your desired number of users. Page 9 Section Access covers shall have a minimum opening dimension of twenty 20 inches mm in diameter.

The conduit shall be of material approved for installation underground beneath buildings and not less than Schedule 40 pipe. Sponsored by: A grease interceptor as described in these standards shall be installed in any business establishment with kitchen facilities including restaurants, cafes, lunch counters, cafeterias, supermarkets, convenience stores, bakeries, bars and clubs, hotels, hospitals, sanitariums, factory or school kitchens, or any other commercial establishment where grease may be introduced into the sewer system.

Southern Nevada shall be considered a dry gas condition area unless specified by the local gas purveyor. Whenever an existing building has a change in use which requires an interceptor or whenever there is an increase in the total number of drainage fixture units served by an existing interceptor.

Connections shall be of the following types: 1 2 3 Pipe fittings such as elbows, tees, and couplings. Select the Upgrade with Redline option in the cart pop up.